Contents
6-5-4-1. Area Setup using the Mouse
The default area will disappear when the left mouse button is clicked.
The motion detection area can be set by click and drag as shown,
Ú One click of the mouse during Motion Area Setup is one cell unit that is
used to sense motion. This unit is how the sensitivity is measured. If
sensitivity is set to 1, then if any movement within this much area will
trigger the alarm. If sensitivity is set to 2, then 2 cells of such size must
sense movement to trigger the alarm and so on.
Ú Refer to picture for the size of 1 cell.
Ú To start recording by motion detection, recording button should be pressed
after setting the above parameters.
- 63 -